Page #21 background imageLoading...
Page #21 background image
RUGGEDCOM RUGGEDCOM RSG2488
Installation Guide
Chapter 2
Installing the Device
Connecting High AC/DC Power 15
Figure 9: Removing a Power Supply
1. Screws 2. Power Supply 3. Slot
3. Install the blank power module assembly into the empy slot to prevent the ingress of dust and dirt.
Section 2.3.2
Connecting High AC/DC Power
To connect a high AC/DC power supply to the device, do the following:
DANGER!
Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make sure
the supplied cover is always installed over high voltage screw-type terminal blocks.
CAUTION!
Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a DC power
supply terminal block. Damage to the power supply may occur.
NOTE
The screw-type terminal block is installed using Phillips screws and compression plates, allowing either
bare wire connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable screws, which
must be removed to make connections.
1. Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.

Table of Contents

Other manuals for Siemens RUGGEDCOM RSG2488

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RSG2488 and is the answer not in the manual?

Siemens RUGGEDCOM RSG2488 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RSG2488
CategorySwitch
LanguageEnglish

Related product manuals