RUGGEDCOM RUGGEDCOM RSG2488
Installation Guide
Chapter 6
Certification
EMI and Environmental Type Tests 47
Test Description Test Levels Severity Levels
Signal Ports
DC Power Ports
IEC 61000-4-12 Damped Oscillatory
AC Power Ports
2.5 kV common,
1 kV differential
mode @ 1 MHz
3
Signal PortsIEC 61000-4-16 Mains Frequency Voltage
DC Power Ports
30 V Continuous,
300 V for 1s
4
IEC 61000-4-17 Ripple on DC
Power Supply
DC Power Ports 10% 3
Signal Ports 2 kVAC (Fail-
Safe Relay Output)
DC Power Ports 1.5 kVDC
Dielectric Strength
AC Power Ports 2 kVAC
Signal Ports 5 kV (Fail-Safe
Relay Output)
DC Power Ports
IEC 60255-5
HV Impulse
AC Power Ports
5 kV
a
Siemens-specified severity levels
IEEE 1613 (C37.90.x) EMI Immunity Type Tests
NOTE
The RSG2488 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for
copper ports.
Test Description Test Levels
Signal ports 5 kV (Failsafe Relay Output)
DC Power Ports
HV Impulse
AC Power Ports
5 kV
Signal ports 2 kVAC
DC Power Ports 1.5 kVDC
IEEE C37.90
Dielectric Strength
AC Power Ports 2 kVAC
Signal ports +/- 4 kV @ 2.5 kHz
DC Power Ports
AC Power Ports
Fast Transient
Earth ground ports
+/- 4 kV
Signal ports 2.5 kV common mode @1MHz
DC Power Ports
IEEE C37.90.1
Oscillatory
AC Power Ports
2.5 kV common, 1 kV
differential mode @ 1 MHz
IEEE C37.90.2 Radiated RFI Enclosure ports 35 V/m