&RPPLVVLRQLQJ
S7-300 Automation System, Hardware and Installation: CPU 312IFM - 318-2 DP
9-12 A5E00203919-01
 ,QLWLDOSRZHURQ
5HTXLUHPHQWV
You must have installed and wired up the S7-300.
Your CPU's mode selector switch must be set to STOP.
,QLWLDOSRZHUXSIRUD&38ZLWKPHPRU\FDUG0&
The CPU 312 IFM has no memory card, but it is covered in this section.
Switch on the PS 307 power supply module.
5HVXOW
The 24 VDC LED on the power supply module is lit.
The 5 VDC LED on the CPU
is lit.
The STOP LED flashes at 2 Hz when the CPU executes an automatic
memory reset.
The STOP LED is lit after memory reset.
The BATF LED is lit if the back-up battery is missing in the CPU (not with
CPU 312 IFM, since not buffered).
1RWH
If you insert a Memory Card and a back-up battery before power is on, the CPU
also requests a memory reset after start-up.