Physical/remote access
If possible, operate the devices only within a protected network area. Attackers cannot access
internal data from the outside when the internal and the external network are separate from
each other.
Limit physical access to the device exclusively to trusted personnel.
The memory card or the PLUG (C-PLUG, KEY-PLUG, CLP) contains sensitive data such as
certi󹪝cates and keys that can be read out and modi󹪝ed. An attacker with control of the
device's removable media could extract critical information such as certi󹪝cates, keys, etc. or
reprogram the media.
Lock unused physical ports on the device. Unused ports can be used to gain forbidden access
to the plant.
We highly recommend that you keep the protection from brute force attacks (BFA) activated
to prevent third parties from gaining access to the device. For more information, see the
con󹪝guration manuals, section "Brute Force Prevention".
If possible, use the VPN functionality to encrypt and authenticate communication for
communication via non-secure networks.
When you establish a secure connection to a server (for example for an upgrade), make sure
that strong encryption methods and protocols are con󹪝gured for the server.
Terminate the management connections (e.g. HTTPS, SSH) properly.
Make sure that the device has been powered down completely before you decommission it.
For more information, refer to "Decommissioning (Page7)".
We recommend formatting a PLUG that is not being used.
Hardware / Software
Use VLANs whenever possible as protection against denial-of-service (DoS) attacks and
unauthorized access.
Restrict access to the device by setting 󹪝rewall rules or rules in an access control list (ACL).
Selected services are enabled by default in the 󹪝rmware. It is recommended to enable only
the services that are absolutely necessary for your installation.
For more information on available services, see "List of available services (Page17)".
To ensure you are using the most secure encryption methods available, use the latest web
browser version compatible with the product. Also, the latest web browser versions of
Mozilla Firefox, Google Chrome, and Microsoft Edge have 1/n-1 record splitting enabled,
which reduces the risk of attacks such as SSL/TLS Protocol Initialization Vector
Implementation Information Disclosure Vulnerability (for example, BEAST).
Ensure that the latest 󹪝rmware version is installed, including all security-related patches.
You can 󹪝nd the latest information on security patches for Siemens products at the Industrial
Security (https://www.siemens.com/industrialsecurity) or Pr
oductCERT Security Advisories
(
https://www.siemens.com/cert/en/cert-security-advisories.htm) w
ebsite.
For updates on Siemens product security advisories, subscribe to the RSS feed on the
ProductCERT Security Advisories website or follow @ProductCert on Twitter.
Enable only those services that are used on the device, including physical ports. Free physical
ports can potentially be used to gain access to the network behind the device.
Security recommendations
3.1Security recommendations
SCALANCE MUM853-1
Operating Instructions, 03/2023, C79000-G8976-C650-05 15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE MUM853-1 and is the answer not in the manual?

Siemens SCALANCE MUM853-1 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE MUM853-1
CategoryNetwork Router
LanguageEnglish

Related product manuals