Function
The reset button has the following functions:
• Restarting the device
To restart the device, press the reset button briey.
Note
If
you make changes to the conguration and restart immediately afterwards with the reset
button, the changes may be lost. If you restart the device using the WBM (menu command
"System > Restart") or using the CLI (command "restart" in the Privileged EXEC Modus), the
conguration changes are always retained.
• Loading a rm
ware le via TFTP
If the normal procedure with the "Load & Save" menu of Web Based Management is
unsuccessful, the reset button can be used to load new rmware. This situation can occur if
there is a power outage during the normal rmware update. You can nd more detailed
information in the section "Downloading new rmware using TFTP without WBM and CLI
(Page63)".
• Resetting the device to factory settings
If you reset, all the settings you have made will be overwritten by factory defaults. If a PLUG
is inserted in the device, the PLUG is also reset to default settings. You can nd additional
information in the section "Restoring the factory settings (Page64)".
NOTICE
Inadvertent reset
An inadvertent reset can cause disturbances and failures in a congured network with further
consequences.
4.9 Congur
ation License PLUG
The CLP (Conguration License PLUG) is used to transfer the conguration of the old device to
the new device when a device is replaced. The CLP is also referred to as PLUG in the description.
The PLUG is available in the following variants:
• PLUG Conguration: The exchangeable storage medium only saves the conguration data of
the device.
• PLUG License: In addition to the conguration data, the exchangeable storage medium
contains a license with which special functions are enabled, e.g. iFeatures.
NOTICE
Loss of the degree of protection
When t
he cover is not mounted correctly, the device loses its degree of protection IP30.
Description of the device
4.9Congur
ation License PLUG
SCALANCE MUM853-1
Operating Instructions, 03/2023, C79000-G8976-C650-05 31