EasyManuals Logo

Siemens SCALANCE MUM853-1 User Manual

Siemens SCALANCE MUM853-1
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
WARNING
EXPLOSION HAZARD
Do not press the reset button if there is a potentially explosive atmosphere.
WARNING
Unsuitable cables or connectors
Risk of explosion in hazardous areas
Only use connectors that meet the requirements of the relevant type of protection.
If necessary, tighten the connector screw connections, device fastening screws, grounding
screws, etc. according to the speci󹪝ed torques.
Close unused cable openings for electrical connections.
Check the cables for a tight 󹪝t after installation.
WARNING
Lack of equipotential bonding
If there is no equipotential bonding in hazardous areas, there is a risk of explosion due to
equalizing current or ignition sparks.
Ensure that equipotential bonding is available for the device.
WARNING
Unprotected cable ends
There is a risk of explosion due to unprotected cable ends in hazardous areas.
Protect unused cable ends according to IEC/EN 60079-14.
WARNING
Improper installation of shielded cables
There is a risk of explosion due to equalizing currents between the hazardous area and the non-
hazardous area.
Ground shielded cables that cross hazardous areas at one end only.
Lay a potential equalization conductor when grounding at both ends.
Connection
6.1Safety when connecting up
SCALANCE MUM853-1
48 Operating Instructions, 03/2023, C79000-G8976-C650-05

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE MUM853-1 and is the answer not in the manual?

Siemens SCALANCE MUM853-1 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE MUM853-1
CategoryNetwork Router
LanguageEnglish

Related product manuals