OpenVPN tunnel between SCALANCE S615 and SINEMA RC Server
2.1 Procedure in principle
SCALANCE S615 Getting Started
26 Getting Started, 03/2015, C79000-G8900-C390-01
Master station - connection to SINEMA RC Server
In the test setup in the internal network, a network node is implemented by a PC
connected to the LAN port of the SINEMA RC Server.
PC: represents a participant in internal network 3
SINEMA RC Server
Connection to the external network via a router
Access to the external network is via a router connected to the WAN port of the SINEMA
RC Server.
Station 1 / 2 - Connection to SCALANCE S615
In the test setup in the internal network, a network node is implemented by a PC
connected to the Ethernet interface P1 of the S615.
PC: represents a participant in internal network 1/2
S615: SCALANCE S module for protection of the internal network 1/2
Connection to the external network via a router
Access to the external network is via a router connected to the Ethernet interface P5 of
the S615.
Required devices/components
Use the following components for setup:
2 x S615 (additional option: a suitably installed standard rail with fittings)
2 x KEY-PLUG SINEMA RC
2 x 24 V power supply with cable connector and terminal block plug
2 x PC each connected to a SCALANCE S615.
1 x PC on which the SINEMA RC Server is installed.
1 x PC that is connected to the SINEMA RC Server.
3 x router
The required network cable, TP cable (twisted pair) complying with the IE FC RJ-45
standard for Industrial Ethernet