You delete name assignment for a VLAN with the no name command.
7.2.4.2 no name
Description
With this command, you delete the name assignment for a VLAN.
Requirement
You are in the VLAN configuration mode.
The command prompt is as follows:
cli(config-vlan-$$$)#
Syntax
Call the command without parameters:
no name
Result
The name of the VLAN is deleted.
Further notes
You assign the VLAN a name with the command name.
7.2.4.3 ports
Description
With this command, you generate a static VLAN entry that specifies the use of the ports. Here,
you configure the following types of ports:
Member ports (tagged ports)
These ports are permanently added to the list of outgoing connections
Untagged ports
These ports transfer data packets without a VLAN marking
Forbidden ports
These ports are not used for communication in a VLAN
The tagged and untagged ports specified with this command are used for outgoing data traffic.
Network structures
7.2 VLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
298 Configuration Manual, 09/2017, C79000-G8976-C324-08