Syntax
Call up the command with the following parameters:
no snmp access <GroupName> {v1|v2c|v3 {auth|noauth|priv}}
The parameters have the following meaning:
Parameter Description Range of values / note
GroupName Name of the group to which access is
deleted
max. 32 characters
Version Selects the version of the protocol used
v1
v2c
v3
Authentication Selects the authentication method.
auth
noauth
priv
Result
The access to an SNMP group is deleted.
Further notes
You configure the setting with the snmp access command.
You display the configured SNMP groups with the show snmp group command.
You display the access configurations for SNMP groups with the show snmp group
access command.
You display the configured SNMP tree views with the show snmp viewtree command.
8.6.2.6 snmp community index
Description
With this command, you configure the details of an SNMP community.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 417