The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
cli-console-timeout [seconds(60-600)]
The parameters have the following meaning:
Parameter Description Range of values / note
seconds Time in seconds until automatic logout
after the last entry
60 ... 600
Default: 300
Result
The time is configured and automatic logout is enabled.
Further notes
You disable automatic logout with the no cli-console-timeout command.
You display the current timeout setting with the show cli-console-timeout command.
4.1.10.8 no cli-console-timeout
Description
With this command, you disable the automatic logout.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no cli-console-timeout
Result
Automatic logout is disabled.
Configuration
4.1 System
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 71