Further notes
You can display the status of this function and other information with the show device
information command.
11.2.2.4 radius-server
Description
With this command, you configure a RADIUS server entry on the RADIUS client.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
radius-server { ipv4 <ipv4-address> | fqdn-name <FQDN> | ipv6 <ipv6-
address> } [auth-port <portno(1-65535)>] [retransmit <1-5>] [key
<secret-key-string>] [primary] [{login | dot1x | login-dot1x}] [test]
The parameters have the following meaning:
Parameter Description Range of values / note
ipv4 Keyword for an IPv4 address -
ipv4-address IPv4 address of the RADIUS server Enter a valid IPv4 address.
fqdn-name Keyword for a domain name -
FQDN Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
If you have stored a suitable do‐
main name, you can specify a host
name.
ipv6 Keyword for an IPv6 address -
ipv6-address IPv6 address of the RADIUS server Enter a valid IPv6 address.
auth-port Keyword for the UDP port number for
authentication
portno Number of the port 1 … 65535
Default: 1812
retransmit Keyword for the number of connection
retries
-
Security and authentication
11.2 RADIUS client
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface