Configuration / project engineering 
  6.3 Factory default 
SCALANCE X-400 
Operating Instructions, 06/2015, C79000-G8976-C186-12 
115 
 
 
Note 
Resetting the IE switch X
-400 to the factory settings is described in the section "SELECT/ 
 
DIP switch (SCALANCE X414-3E only) 
The four DIP switches on the CPU module are set to ON when supplied. 
 
Note 
Prior to commissioning check the switch settings.
 
● 
 
is set to ON: The SCALANCE X414-3E is redundancy manager. 
● 
 
no function. 
● 
 
are set to ON: You can only configure ring redundancy with software (CLI, WBM). 
"Automatic Redundancy Detection" is set as the mode. 
 
Note 
With the SCALANCE X408
-
2 basic device no DIP switches exist. The settings for RM, SB 
and R1
, R2 (ring ports) can be made using software. The RM can be enabled/disabled 
using the SELECT/SET button.
 
The default settings for RM and ring ports are the same for the basic devices 
SCALANCE
 X414-3E and SCALANCE X408-2. 
R1 and R2 enable ring redundancy when the product ships. 
 
Note 
in this mode, RSTP/STP cannot be enabled.