SCALANCE X-400
Operating Instructions, 06/2015, C79000-G8976-C186-12
113
Configuration / project engineering
6
6.1
Replacing a device
Replacing a device
Note
If you replace
an IE Switch X-400, remember the following:
Make the same settings on the DIL switches of the new SCALANCE X414-3E device as
they were on the old device.
Install the identical media module configuration and, if applicable with the SCALANCE
X414-3E, the extender module configuration on the new device as was on the old device.
Use the C-PLUG of the old device in the new one. This means that the previous device
configuration will be adopted automatically when the new device starts up.