Installation
4.4 Installing / uninstalling the extender modules for SCALANCE X414-3E
SCALANCE X-400
98 Operating Instructions, 06/2015, C79000-G8976-C186-12
7. Using a slotted screwdriver with a 2.8 mm wide blade, tighten the two captive slug screws
on slot 11. The screws lock the two guide bolts, so do not use excessive force when
tightening them.
8. Fit a suitable cover on slot 11 of the basic device.
Note
The basic device must not be used permanently without the right side panel.