6.5 Connecting functional ground
Installation on a DIN rail
The device is grounded over the DIN rail.
S7 standard rail
The device is grounded over its rear panel and the neck of the screw.
Wall mounting
The device is grounded by the securing screw in the unpainted hole.
Please note that IE Switches X-300 must be grounded over one securing screw with minimum
resistance.
If an IE Switch X-300 is mounted on a non-conducting base, a grounding cable must be
installed. The grounding cable is not supplied with the device. Connect the paint-free surface
of the IE Switch X-300 to the nearest grounding point using the grounding cable.
19" rack mounting
24 VDC variant:
Grounding is via the mounting bracket on the device or alternatively/additionally via the bolts
on the rear of the device.
100 to 240 VAC variant:
Grounding is via the mounting bracket on the device or alternatively/additionally via the bolts
on the rear of the device.
Connecting
6.5 Connecting functional ground
SCALANCE X-300
54 Compact Operating Instructions, 11/2019, A5E00982643-18

Other manuals for Siemens SCALANCE X308-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2 and is the answer not in the manual?

Siemens SCALANCE X308-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2
CategorySwitch
LanguageEnglish

Related product manuals