Figure 9-1 FDA and IEC approvals
CAUTION
Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Mechanical stability (in operation)
Device IEC 60068-2-6 vibration IEC 60068-2-27 shock
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X304-2FE ● ●
X306-1LD FE ● ●
X307-3 ● ●
X307-3LD ● ●
X308-2 ● ●
X308-2LD ● ●
X308-2LH ● ●
X308-2LH+ ● ●
X310 ● ●
X310FE ● ●
X320-1FE ● ●
X320-3LD FE ● ●
Installation guidelines
The devices meet the requirements if you adhere to the installation and safety instructions
contained in this documentation and in the following documentation when installing and
operating the devices.
● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (
https://
support.industry.siemens.com/cs/ww/en/view/27069465)
● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https://
support.industry.siemens.com/cs/ww/en/view/84922825)
● "EMC Installation Guidelines" configuration manual (https://support.industry.siemens.com/
cs/ww/en/view/60612658)
Certifications and approvals
SCALANCE X-300
Compact Operating Instructions, 11/2019, A5E00982643-18 81