EasyManua.ls Logo

Siemens SIDOOR ATD401W - Page 139

Siemens SIDOOR ATD401W
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Task
The relay module's relay contacts can be used to report the following door states to the higher-
level controller:
Table 5-5 SIDOOR ATD401W door states
Relay con‐
tact
Designation Function
X11 CLOSE
(closed)
The system's internal door state "closed" is signaled via this relay (relay contact is closed). This
state is not only position-dependent. Note the following conditions:
The "closed" state can only be achieved with a drive order
The "closed" state cannot be achieved by external pushing
The "closed" state can be terminated by means of a drive order or external pushing
X12 REVERSE
(reversing)
The relay is additionally in󹪞uenced by the sensor con󹪝guration (parameter p4600). See also
section Sensors and external sensor interface module (Page 166).
Sensor function test inactive
The control signals that the current drive order's direction is reversed.
Example: automatic reversing due to an obstruction, provided that the applicable reversing
response is parameterized.
The relay is active as long as the current drive order is reversed.
Sensor function test active
The "TestOUT" sensor function test signal is output.
X13 OPEN The system's internal door state "open" is signaled via this relay (relay contact is closed).
This state essentially depends on the current door position.
The "open" state can be achieved both by means of a drive order and also by external
pushing.
The state can be terminated by means of a drive order or external pushing
X11 and
X13
FAULT There is a fault in the system if both relays are simultaneously active (relay contacts closed).
Connection
DANGER
Risk of injury from dangerous electrical voltages
Only safety extra-low voltages may be applied to the relay module. <=30 V DC.
Terminal circuit diagram of the relay contacts
=X
FORVH
;
$XI
RSHQ
;
5HYHUVLHUW
UHYHUVH
;
Controllers
5.5 Relay and 󹪝eldbus interfaces
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA 137