7.1.4 Technical specications
Article number 6FB1112-0AT20-3PS0
General information
Product brand name SIDOOR
Product type designation NT40
Installation type/mounting
Mounting type Four 5 mm screws
Supply voltage
Rated value (AC) 230 V
relative symmetrical tolerance of the supply voltage 15 %
Line frequency
• permissible range, lower limit
50 Hz
• permissible range, upper limit
60 Hz
Input current
Current consumption for 2 s, max. 3.5 A
Rated value at 230 V AC 0.7 A
Operational current of fuse protection at input, min. 6 A
Operational current of fuse protection at input, max. 10 A
Tripping characteristic class of fuse protection at input B
Output voltage
Rated value (DC) 36 V; SELV
Relative symmetrical tolerance of the output voltage 3 %
Output current
Current output (rated value) 2.5 A
Temporary overload current (for 2 s maximum) 15 A
Power
Active power input, max. 100 W
Emitted active power, max. 100 W
Emitted active power (restricted to 2 s) 540 W
Eciency at 230 V AC (with 100 W emitted active power) 90 %
Active apparent power, max. 650 V·A
Isolation
Overvoltage category 2
Degree of pollution 2
Degree and class of protection
IP degree of protection IP54
Equipment protection class I
Standards, approvals, certicates
CE mark Yes
EAC (formerly Gost-R) Yes
TÜV Inspectorate approval Yes
China RoHS compliance Yes
Standard for EMC EMC Directive 2004/108/EC, EN 12015, EN 12016
Power supply
7.1 SIDOOR NT40
ATD4xxW for industrial applications
240 System Manual, 06/2022, A5E51901827B AA