7.3.5 Technical specications
7.3.5.1 SIDOOR TRANSFORMER UL
Article number 6FB1112-0AT21-2TR0
General information
Product version Power supply unit for SIDOOR controllers
Installation type/mounting
Mounting type Hexagon head bolt M6, L > 70 mm
Supply voltage
permissible range, lower limit (AC) 220 V
permissible range, upper limit (AC) 240 V
relative symmetrical tolerance of the supply volt‐
age
10 %
Line frequency
• permissible range, lower limit
50 Hz
• permissible range, upper limit
60 Hz
Mains lter
• integrated
Yes
Input current
Current consumption, max. 1.6 A
Operational current of fuse protection at input,
min.
6 A
Operational current of fuse protection at input,
max.
10 A
Tripping characteristic class of fuse protection at
input
D6, C10
Output voltage
RMS value (pulsating DC voltage at full load) 17.3 V; at 230 V AC
RMS value (pulsating DC voltage at full load),
min.
16.5 V
RMS value (pulsating DC voltage at full load),
max.
18 V
RMS value (pulsating DC voltage at 0.7 mA peak
current), max.
27 V; At 264 V AC
Power
Emitted active power, max. 115 W; Average value above 10 s
Standards, approvals, certicates
CE mark Yes
EAC (formerly Gost-R) Yes
RoHS conformity Yes
China RoHS compliance Yes
Standard for EMC EN 12015 / EN 12016 / EN 61000-6-2 / EN
61000-6-3 / EN 61000-3-2 / EN 61000-3-3
Power supply
7.3 SIDOOR TRANSFORMER UL
ATD4xxW for industrial applications
256 System Manual, 06/2022, A5E51901827B AA