Note
ATD420W / ATD430W Access protection to the parameters
The write protection must be activated via parameter p90 for the SIDOOR ATD420W and
ATD430W controllers. This way the change of parameters is blocked via the service menu.
Note
After the optimal parameter settings have been determined, note them in the conguration
protocol (see appendix Conguration record (Page 339)). Have this record to hand when you call
the Hotline.
Note
Parameter changes
Parameters should always be adjusted during normal operation with the door at standstill,
because the controller then accepts the values immediately.
As of V1.09: The parameter changes are also applied in initial mode with standstill of the door.
5.9.1 Service buttons
Overview
H401
LEARN RUN
OPEN CLOSE
S402 S403S401
6,'225$7'[[:
① 7-segment display
② Learn run button
③ Service button OPEN
④ Service button CLOSE
Figure 5-8 Overview of minimal editor
5.9.1.1 Operation using service buttons
7-segment display "H401"
You can see the operating states on the "H401" 7-segment display. You can nd the description
of the 7-segment display in the section Operating state display (Page 303).
Controllers
5.9 Operation and conguration of the control unit
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA 177