The I&M records consists of the following parameters:
Table 5-16 I&M 0 and I&M 1 to 4 data
I&M record Fields (standardized) Access authorization
I&M 0 MANUFACTURER_ID
ORDER_ID
SERIAL_NUMBER
HARDWARE_REVISION
SOFTWARE_REVISION
REV_COUNTER PROFILE_ID
PROFILE_SPECIFIC_TYPE
IM_VERSION
IM_SUPPORTED
Read
I&M 1 TAG_FUNCTION
TAG_LOCATION
Read and write (on DAP)
I&M 2 INSTALLATION_DATE
I&M 3 DESCRIPTOR
I&M 4 SIGNATURE
Topology information
The Link Layer Discovery Protocol (LLDP) is used to detect the network neighborhood and thus
also to determine topology information. The status of individual connections can be read out at
any time.
Network diagnostics
The Simple Network Management Protocol (SNMP) is used to support network diagnostics. The
ATD430W IO device supports MIB-II for TCP/IP in accordance with RFC1213.
Port-related statistics
The topology presentation data is stored in the physical device of the ATD430W IO device. The
PDEV data is addressed as from subslot 0x8000. From a communication perspective, the
ATD430W IO device always consists of the interface and the ports 1 and 2.
The PDEV is represented by the following submodules of the device access point (DAP):
Submodule 0x8000 → Interface
Submodule 0x8001 → Port1
Submodule 0x8002 → Port 2
Automatic addressing
The Discovery and basic Con󹪝guration Protocol (DCP) is compulsory for the automatic
assignment of IP addresses.
Media redundancy
In the case of PROFINET, the Media Redundancy Protocol (MRP) is used for the media redundancy
of ring topologies. The ATD430W IO device assumes the role of an MRP client. The MRP manager
function is not supported.
Controllers
5.5 Relay and 󹪝eldbus interfaces
ATD4xxW for industrial applications
154 System Manual, 06/2022, A5E51901827B AA