ASDRV signal
The ASDRV signal is located in the high byte of TZW2 (bit 8). It has a binary structure.
Table A-32 ASDRV signal
ASDRV signal
value
Name Description
0 AssistedDrive active An external assisting force within the parameterized threshold
values has been found
1 AssistedDrive inac‐
tive
An external assisting force within the parameterized threshold
values has not been found
You will 󹪝nd further information about the ASDRV signal and the corresponding drive function
in section AssistedDrive (Page 83).
ASStp signal
The ASStp signal is located in the high byte of TZW2 (bit 9). It has a binary structure.
Table A-33 ASStp signal
ASStp signal
value
Name Description
0 ImpulseStop inac‐
tive
An external opposing force within the parameterized limit val‐
ues was not found
1 ImpulseStop active An external opposing force within the parameterized limit val‐
ues was found
You will 󹪝nd further information about the ASStp signal and the corresponding drive function in
the section ImpulseStop (Page 81).
DTErrAND0 signal
Firmware version V1.12 or higher:
The DTErrAND0 signal is located in the upper byte of the TZW2 (bit 6). It has a binary structure.
Table A-34 DTErrAND0 signal
DTErrAND0 sig‐
nal value
Name Description
0 No discrepancy er‐
ror AND0
No discrepancy error was detected at function block AND0.
1 Discrepancy error
AND0
A discrepancy error was detected at function block AND0.
You can 󹪝nd more information on the DTErrAND0 signal and the corresponding function in the
section Discrepancy analysis blocks (Page 99).