Technical specifications   
8.4 Climatic ambient conditions 
  Basic Panels 2nd Generation 
100  Operating Instructions, 10/2016, A5E33293231-AB 
 
Climatic ambient conditions 
8.4.1
 
The following information applies to a device that is stored for an extended period in its 
original packaging.  
The device meets the requirements according to IEC 60721-3-1, Class 1K2 with the 
following amendments and limitations: 
 
Atmospheric pressure  1080 ... 660 hPa, corresponds to an elevation of -1000 to 3500 m 
10 ... 90%, without condensation 
Pollutant concentration  SO2: < 0.5 ppm; relative humidity < 60%, no condensation 
H
2
S: < 0.1 ppm; relative humidity < 60%, no condensation 
 
Transport and short-term storage 
The following information is for a device that is transported and temporarily stored in its 
original packaging.  
The device meets the requirements according to IEC 60721-3-2, Class 2K2 with the 
following amendments and limitations: 
 
1080 ... 660 hPa, corresponds to an elevation of -1000 ... 3500 m 
10 ... 90%, without condensation 
Pollutant concentration  SO2: < 0.5 ppm; relative humidity < 60%, no condensation 
H
2
S: < 0.1 ppm; relative humidity < 60%, no condensation 
 
 
Note 
Ensure that no condensation (dewing) develops on or inside the HMI device after 
transporting it at low temperatures or after it has been exposed to extreme temperature 
fluctuations.
 
evice must have acquired room temperature before it is put into operation. Do not 
expose the HMI device to direct radiation from a heater. If dewing has developed, wait 
approximately 4 hours until the HMI device has dried completely before switching it on.