Appendix
A.3 Connection of serial devices via Freeport protocol
SIMATIC RF120C
Operating Instructions, 02/2021, C79000-G8976-C328-03
53
A.3.5 Block-specific error messages
The following table lists the block-specific error codes that can occur when working with
optical handheld readers, access control readers or serial devices.
Table A- 4 Block-specific error messages
Error ID
Meaning
0xE1FE0300
Address error in command (≠ "0x0000", "0x0002", "0xFFFF")
0xE2FE0100
Negative acknowledgment or bad frame from the reader
0xE4FE0400
New data was received before existing data was fetched.
Scan operation: The newest data is lost.
With the "Write" command, the oldest acknowledgments are lost without an error
message being generated.
0xE4FE8D00
Internal communication error
0xE5FE0400
Invalid data block number (DBN) on the reader/communication module
0xE6FE0100
Unknown command, incorrect command parameters or unauthorized command
chaining (incorrect length specification)
0xE6FE0500
"Reset_Reader" necessary