EasyManuals Logo

Siemens SIMATIC Ident Operating Instructions

Siemens SIMATIC Ident
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Appendix
A.3 Connection of serial devices via Freeport protocol
SIMATIC RF120C
Operating Instructions, 02/2021, C79000-G8976-C328-03
53
A.3.5 Block-specific error messages
The following table lists the block-specific error codes that can occur when working with
optical handheld readers, access control readers or serial devices.
Table A- 4 Block-specific error messages
Error ID
Meaning
0xE1FE0300
Address error in command (≠ "0x0000", "0x0002", "0xFFFF")
0xE2FE0100
Negative acknowledgment or bad frame from the reader
0xE4FE0400
New data was received before existing data was fetched.
Scan operation: The newest data is lost.
With the "Write" command, the oldest acknowledgments are lost without an error
message being generated.
0xE4FE8D00
Internal communication error
0xE5FE0400
Invalid data block number (DBN) on the reader/communication module
0xE6FE0100
Unknown command, incorrect command parameters or unauthorized command
chaining (incorrect length specification)
0xE6FE0500
"Reset_Reader" necessary

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals