The device is designed for industrial applications. It conforms to the following standards:
● Requirements for emissions EN 61000-6-4: 2007
● Requirements for interference immunity EN 61000-6-2: 2005
Under certain circumstances you can use the device in a mixed-use zone. A mixed-use zone
is used for housing and commercial operations that do not have a significant impact on
residents.
When you use the device in a mixed-use zone, you must ensure that the limits of the generic
standard EN 61000-6-3 regarding emission of radio frequency interference are observed.
Suitable measures for achieving these limits for use in a mixed-use zone include:
● Installation of the device in grounded control cabinets
● Use of filters in electrical supply lines
Individual acceptance is required.
Note
IFP Basic is not intended for use in residential area
The device is not intended for use in residential areas. Operation of a device in residential
areas can have a negative influence on radio or TV reception.
Use with additional measures
The device should not be used at the following locations unless additional measures are
taken:
In locations with a high degree of ionizing radiation
● In locations with severe operating conditions, for example, due to:
– Corrosive vapors, gases, oils or chemicals
– Strong electrical or magnetic fields of high intensity
● In systems that require special monitoring, for example, in:
– Elevators
– Systems in especially hazardous rooms
If the device is subjected to greater shocks or vibrations, you must take appropriate
measures to reduce acceleration or amplitudes.
We recommend mounting the device on damping materials, such as rubber-metal vibration
dampers.