Loading...
Technical information
7.5 Technical specifications
IFP Basic
62 Operating Instructions, 03/2019, A5E46178354 - AB
Climatic ambient conditions
The following table shows the climatic ambient conditions for operation of the device.
Ambient conditions
Permitted range
Comments
Temperature for IFP1200 /
IFP1500 / IFP 1900 Basic:
horizontal mounting
0 to 45 °C
Vertical mounting
0 to 45 °C
Tilt angle max. 45°
Temperature for IFP2200
Basic:
horizontal mounting
0 to 40 °C
Vertical mounting
0 to 40 °C
Tilt angle max. 45°
Relative humidity 10 to 85% at 30 °C, no condensa-
tion
Atmospheric pressure,
operation elevation
1080 to 689 hPa Corresponds to an elevation
of -1000 to 3000 m
Note the information in section "Notes about usage (Page 14)" .
7.5.2.3
Electromagnetic compatibility
Pulse-shaped interference
The following table shows the electromagnetic compatibility of modules with regard to pulse-
shaped interference. This requires the device to meet the specifications and directives for
electrical installation.
Pulse-shaped interference
Test voltage
Degree of
severity
Electrostatic discharge
in accordance with IEC
61000-4-2
Air discharge: ± 8 kV
3
Contact discharge: ± 4 kV 2
Bursts
(high-speed transient
interference)
in accordance with
IEC 61000-4-4
± 2 kV power supply cable
± 1 kV signal cable, < 30 m
3
Surge in accordance with
IEC 61000-4-5
1 kV line-to-line of DC port
2 kV line-to-earth of DC port
Asymmetrical coupling ± 2 kV power supply cable
DC voltage with protective elements
3
Symmetrical coupling 1 kV power supply cable
DC voltage with protective elements
3

Table of Contents