Process interfacing via an automation system (PLC, PC)
9.1 Integration via PROFINET IO without CM
SIMATIC MV500
104 Operating Instructions, 05/2019, C79000-G8976-C494-02
You have a variety of options available to integrate the optical reader into your automation
system.
Via the combination interface (DI/DQ, RS232 and CM):
Integration via a communication module and Ident profile
Integration via RS232
Integration via DI/DQ
Via the Ethernet interface (PROFINET IO, TCP/IP):
Integration using the Ident profile and FB 79 via PROFINET IO without an additional
communication module.
Integration via TCP/IP
This section explains the various options for process connection.
9.1 Integration via PROFINET IO without CM
You can use the MAC address to operate the optical reader via PROFINET IO without using
a communication module. The reader has two MAC addresses. The MAC address printed on
the housing is the interface MAC address. The port MAC address corresponds to the
interface MAC address +1.
Note
Compatibility and device replacement of SIMATIC MV440 and SIMATIC MV540
Note that the SIMATIC MV440 and SIMATIC MV540 devices are mutually compatible and
can be exchanged in a PROFINET IO network without any problems.
You
can find detailed information on the compatibility of the devices in the section
"
Functional description (Page 21)".
Integrating using the GSD file
The properties of the reader are stored as PROFINET IO devices in the GSD file provided.
You can integrate the reader into controllers using the GSD file.
Note
Configuration software
The following configuration was created with STEP 7 Professional (TIA Portal). Alternatively,
you can integrate and configure the reader in STEP
7 Classic (HW Config) or in third-party
controllers.
As of STEP 7 V15, the SIMATIC MV500 optical readers are already integrated in the TIA
Portal.