Image processing
3.1 Code reading (1D/2D codes)
SIMATIC MV500
36 Operating Instructions, 05/2019, C79000-G8976-C494-02
3.1.2.3 QR codes
Note
Maximum code dimension/unsupported code types
Codes with a maximum code dimension of 89 x 89 can be read.
The following code types are not supported: Micro QR code, Macro QR code.
The recognition process of the optical reader allows reliable and fast reading of printed QR
codes of good quality.
Range of application
The range of imaging sizes ranges from 5 to 35 pixels per cell. The range is static.
The codes can have any alignment in the image.
The code can be printed both dark on a light background and light on a dark background.
The viewing angle of the optical reader to the surface can be between 70° and 90°.
The diameter of the cells must be the same size over the entire code field.
The contrast between cells and the background must be approximately the same over the
entire code field.
The image background must have a homogeneous brightness, for example no texture
such as stripes.
3.1.2.4 PDF417 codes
Note
Unsupported code types
The following code types are not supported: Truncated PDF417, Macro PDF417, Micro
PDF417.
The recognition process of the optical reader allows reliable and fast reading of printed
PDF417 codes of good quality.
Range of application
The codes can have any alignment in the image.
The code can be printed both dark on a light background and light on a dark background.
Codes with a bar width ≥ 3 pixels and in which the height of a single row of symbols is ≥ 9
pixels can be read.
The width of the black and white bars must be uniform over the entire code field.
The viewing angle of the sensor to the surface can be between 70° and 90°.