Technical data
11.3 Technical specifications built-in ring light
SIMATIC MV500
198 Operating Instructions, 05/2019, C79000-G8976-C494-02
11.3 Technical specifications built-in ring light
Table 11- 3 Technical specifications of the built-in ring lights for SIMATIC MV500
6GF3540-8DAxx
Product type designation
Built-in ring light for SIMATIC MV500
Optical data
Lighting distance (max.)
8DA11: 0.8 m
8DA13: 1.5 m
8DA33: 1.5 m
8DA41: 0.8 m
Light color / wavelength
(relative luminosity 0.2 ... 1.0)
8DA11: Red / 625 nm
8DA13: Red / 625 nm
8DA33: White / 6500 K
8DA41: IR / 850 nm
Flash mode
Duty cycle 8%
Max. exposure time 10 ms
Permitted ambient conditions
Ambient temperature
During operation 0 … +50 °C
During transportation and storage -20 … +70 °C
Relative humidity (max.)
95%
Design, dimensions and weight
Dimensions (∅ × H)
54 × 54 mm
Weight
20 g
Standards, specifications, approvals
MTBF
152 years