6 Programmed Communication Connections
A-168
S7-CPs for Industrial Ethernet Configuring and Commissioning
Release 01/2007
C79000-G8976-C182-07
6.4 Parameter Field for System Data
(CP Networking)
Meaning
Below, you can see the subfields that are relevant for networking the CP. These
must be specified in the parameter field for system data.
Some applications do not require all the subfield types - refer to the table for
details.
Structure
Subfield 1
Subfield n
Subfield 2
ID = 0
Type = 0
Number of subfields = n
Usable Subfields
Table 6-4
Subfield
Parameter
ID Type
*)
Special Features / Notes
(Please refer also to the general
description in Table 6-10 Page A-177)
Use
( mandatory
/ optional)
1 SUB_IP_V4 Local IP address m
2 SUB_NETMASK - m
8 SUB_DEF_ROUTER - m
4 SUB_DNS_SERV_ADDR This subfield can occur from 0 to 4 times.
The first entry is the primary DNS server.
o
14 SUB_DHCP_ENABLE 0: No DHCP
1: DHCP
o
15 SUB_CLIENT_ID - o
*) The general properties of the subfield types are described below in Section 6.6.

Table of Contents

Other manuals for Siemens SIMATIC NET S7-300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET S7-300 and is the answer not in the manual?

Siemens SIMATIC NET S7-300 Specifications

General IconGeneral
Product Type DesignationSIMATIC NET S7-300
MountingDIN rail mounting
Protection ClassIP20
CPU ModelsVarious models available (e.g., CPU 312, CPU 314)
Communication InterfacesMPI, PROFIBUS DP
Power Supply24 V DC power supply required. Different power supply modules available.
I/O ModulesDigital input modules, digital output modules, analog input modules, analog output modules
ProgrammingSTEP 7 software
Supply Voltage24V DC or 120/230V AC (depending on model)
Digital InputsAvailable via digital input modules
Digital OutputsAvailable via digital output modules
Analog InputsAvailable via analog input modules
Analog OutputsAvailable via analog output modules
Communication FunctionsMPI, PROFIBUS DP, Ethernet (depending on model)
ProtocolsMPI, PROFIBUS DP, TCP/IP (depending on model)
Operating Temperature0°C to 60°C
Storage Temperature70 °C
MemoryDepends on CPU model (e.g., 32 KB to 1.5 MB)