Programming
5.1 Programming with STEP 7 (TIA Portal)
Technology module TM FAST (6ES7554-1AA00-0AB0)
34 Equipment Manual, 04/2023, A5E52301130-AA
Status parameter
Error codes or status information are output as word at the Status output.
Code
Meaning Remedy
(W#16#...)
0000
No error.
7000
No job in progress.
7001
Writing of data record 100 is not yet completed.
7002
Reading of data record 100 is not yet completed.
8001
The module specified at the HWID input parameter is not
a TM FAST.
Ensure that the hardware identifier of the
TM FAST is specified at the HWID input parame-
ter.
8002
8003
An error has occurred using a system function.
Make sure that the CPU can access the
TM FAST.
8004
8005