5
5.5 SIMODRIVE POSMO A functions
5-188
Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
The brake sequence control operates with the ”open holding brake”
output signal. The signal can be output as follows:
Motor with integrated holding brake (only 300 W motors)
No additional wiring is required for the brake sequence control.
Motor with external holding brake
The external holding brake is controlled using a digital output with
function number 95 (open holding brake).
The following must be observed:
– Output terminal X5, I/Q1, I/Q2
– Activated via P56.4 and P56.6
– Parameterizing the output terminal ––> refer to Chapter 5.5.10
– Connecting up the output terminal ––> refer to Chapter 2.3
– The relay for the holding brake is connected at the parameter-
ized output terminal.
The following parameters are available for the ”Holding brake” function:
P31 Function, terminal 1
P32 Function, terminal 2
P56.4 Open holding brake
P56.5 Monitoring, holding brake undervoltage
P56.6 Open the holding brake, also for an external holding brake
P58 Holding brake, brake opening time
P59 Speed, close holding brake
P60 Holding brake, brake delay time
P61 Holding brake, controller inhibit time
The following signals are relevant for the ”holding brake” function:
Input signal
– Input terminal (X5, I/Q1, I/Q2)
Function number 26 Open holding brake
– PROFIBUS
Control signal STW.15 Open holding brake
Output signal
– Output terminal (X5, I/Q1, I/Q2)
Function number 95 Control external holding brake
Connecting the
holding brake
Parameter
(refer to Chapter
5.6.2)
Signals
(refer to Chapter
5.5.10)
5 Description of the Functions
02.9904.01