5
5.6 Parameters for SIMODRIVE POSMO A
5-217
Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
P0054 / 36 P gain, speed controller standstill
300W
Min Standard Max Unit Data type Effective
1 2 100 I4 immed.
This parameter specifies the P gain for axis at standstill.
Note:
Refer to P56.2
The parameter value can be changed while traversing.
075W
Min Standard Max Unit Data type Effective
1 5 100 I4 immed.
This parameter specifies the P gain for axis at standstill.
Note:
The following applies before SW 1.2: Max. value = 40
The following applies before SW 1.4: Min. value = 0
Refer to P56.2
The parameter value can be changed while traversing.
P0055 / 37 Signal position
300W 075W
Min Standard Max Unit Data type Effective
MSR C4 RO
Last position for external block change or when canceling the program block by withdrawing the
start byte condition.
Note:
The following is valid for the position for rotary axis:
The following applies before SW 1.3: ––> no modulo evaluation
The following applies from SW 1.3: ––> modulo evaluation
P0056 / 38 Operating options
300W 075W
Min Standard Max Unit Data type Effective
0 0 FFFF Hex V2 immed.
Bit 1.0 Drive referenced and behavior after restart (from SW 1.2)
= 00: The motor is referenced when powering-up again if it had already been
referenced when powered-down and was stationary. The behavior is as it was
before SW 1.2.
= 01: The motor is referenced when powering-up again if it was already referenced
when powered-down and was not stationary (ZSW.13).
= 1x: The motor is not referenced when powering-up again.
(x: the bit can either 0 or 1)
The following applies from SW 2.0:
The drive is always dereferenced in the ”Speed setpoint” operating mode (P930). Bit 0
and bit 1 have no function in this operating mode.
Bit 2 P gain at standstill (from SW 1.3)
= 0: P gain of holding controller active (P57)
= 1: Speed controller P gain active (P54)
The following applies from SW 2.0:
The speed controller is always active in the ”Speed setpoint” operating mode (P930).
Bit 2 has no meaning here.
P54 is effective at zero speed.
5 Description of the Functions
02.9904.0108.06