EasyManua.ls Logo

Siemens SIMODRIVE POSMO A

Siemens SIMODRIVE POSMO A
295 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
5.6 Parameters for SIMODRIVE POSMO A
5-224
Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
P0100 / 64 Control word simulation
300W 075W
Min Standard Max Unit Data type Effective
0 0 FFFF V2 immed.
If the cyclic communication with Master Class 1 is interrupted for more than 3 seconds, this
control word is used. All terminal signals remain active with priority.
= 0 ––> no simulation
= 17471 dec (= 443F hex) ––> value recommended for simulation
Note:
The parameter value can be changed while traversing.
P101 must be > 0.
When operating the system with Master Class 2 alone (SimoCom A), the simulation mode is
activated immediately when making entries in P100.
Available from SW 1.2.
P0101:11 / 65 Block sequence in standalone operation
300W 075W
Min Standard Max Unit Data type Effective
0 0 27 I2 immed.
For standalone operation, a maximum of 10 traversing blocks can be entered in the range 3 to
27 in P101:11.
These specified blocks are executed one after the other in the standalone mode.
P101:0 ––> no significance
P101:1 ––> 1st block
P101:2 ––> 2nd block, etc.
Note:
The parameter value can be changed while traversing.
Available from SW 1.2.
P0700 / 2BC Operating mode selector switch
300W 075W
Min Standard Max Unit Data type Effective
122–I2PO
This parameter is used for selecting the operating mode.
Operating mode changes only take effect when the parameter set is saved in the FEPROM
(P971 0 ––> 1) followed by a Power-On Reset (P097 0 ––> 1).
If SimoCom A is in use, the operating mode should be selected via the configuration dialog.
The following operating modes are supported:
1 ––> Speed setpoint
2 ––> Positioning
The parameter corresponds to parameter 930.
Note:
Before changing the operating mode load factory default setting via P970.
This allows achieving a pre-defined initial status.
Available with software version 2.0 and higher.
5 Description of the Functions