P0954 / 3BA Additional information on faults/warnings
300W 075W
Min Standard Max Unit Data type Effective
––––I2RO
The parameter indicates, bit-coded, which supplementary information is available.
The additional information allows to diagnose the faults and warnings exactly.
Bit0 corresponds to Supplementary information 900,
Bit1 corresponds to Supplementary information 901, etc.
Note:
SimoCom A:
Read about possible supplementary information in the online help:
Help ––> Help topics ––> Index ––> 900...911
User Manual:
The description of the faults/warnings, how they can be acknowledged as well as a list of all the
faults/warnings is provided in Section ”Fault handling and diagnostics”.
Refer to the index entry ”Faults/Warnings”.
See also P947 and P953.
Available from SW 1.4.
P0964:8 / 3C4 Drive identification
300W 075W
Min Standard Max Unit Data type Effective
––––V2RO
Indices:
0 Siemens = 42d
1 Drive type POSMO A 75W/300W = 1201/1202
2 Firmware version (x.yy.zz)
3 Firmware date (year) (xxxx decimal)
4 Firmware date (day/month) (ddmm decimal)
5 No. of axes (always 1)
6 No. of option modules (always 0)
7 Gearbox code
Note:
Available from SW 1.4.
P0967 / 3C7 Control word
300W 075W
Min Standard Max Unit Data type Effective
0 0 FFFF Hex V2 immed.
This parameter corresponds to the control signals ”control word (STW)”.
Note:
The following applies from SW 1.4:
If the Class 2 DP master has control authority, then control is realized via this parameter.
The following applies from SW 2.0:
The meanings of bits 4, 5, 6, 8, 9, 11, 12, 13 and 14 depend on the active operating mode.
SimoCom A:
Please consult the online help for more detailed information:
Help ––> Help topics ––> Index ––> PROFIBUS diagnostics
User Manual:
Bit assignment, refer to Section ”Communications via PROFIBUS-DP”.
Refer to the index entry ”Process data”.
5 Description of the Functions
02.9904.0108.06

Table of Contents

Other manuals for Siemens SIMODRIVE POSMO A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE POSMO A and is the answer not in the manual?

Siemens SIMODRIVE POSMO A Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE POSMO A
CategoryEngine
LanguageEnglish

Related product manuals