Pulling on drive output elements
Requirements:
The coupling and/or the drive output element must be appropriately dimensioned for the
operating case at hand.
Observe the coupling manufacturer's instructions.
Make sure that the balancing type of the drive output element correctly matches the type
of balance of the rotor.
Use only ready drilled and balanced drive output elements. Check the hole diameters and
the balancing status before pulling them on. Thoroughly clean the shaft extension.
Pulling on:
Heat up the drive output elements to expand them before pulling them on. Select the
temperature di󹪜erence for the heating process to suit the coupling diameter, 󹪝t and
material. Observe the coupling manufacturer's instructions.
Drive output elements may only be pulled on or pulled o󹪜 with the correct equipment.
The drive output element must be pulled on in one continuous operation via the front
thread holes in the shaft or pushed on by hand.
Do not use a hammer, as this will damage the bearings.
Withdrawing drive output elements
Mounting drive output elements
Only transfer radial or axial forces speci󹪝ed in the catalog to the machine bearings via the
shaft extension.
Assembly
5.5Installing the machine
1LE5, 1PC4 shaft heights 280 ... 355
Operating Instructions, 11/2022, A5E41454666A 63