EasyManua.ls Logo

Siemens SIMOTION C - Page 172

Siemens SIMOTION C
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
10.1 Technical data
SIMOTION C
172 Operating Instructions, 02/2012
DP slave connections
Table 10- 3 Number of DP slave connections
Number of DP slave connections Max. 64
PROFINET device connections
Table 10- 4 Number of PROFINET device connections
Number of PROFINET device connections Max. 64
Address areas
Table 10- 5 Address areas
Input address area, total
2 Kbytes for C230-2
4 Kbytes for C240 / C240 PN
Output address area, total
2 Kbytes for C230-2
4 Kbytes for C240 / C240 PN
Process image inputs 64 bytes
Process image outputs 64 bytes
Connection values
Table 10- 6 Connection values
Supply voltage 24 V DC (permissible range: 20.4 to 28.8 V)
Power consumption from 24 V
typically 0.9 A (inputs/outputs open)
typically 1.2 A (with 4 encoders, 5 V)
typically 1.9 A (with 4 encoders, 24 V)
Power loss 15 W
Starting current 8 A
Encoder supply 5 V max. output current 1.2 A
Encoder supply 24 V max. output current 1.2 A
Dimensions and weight
Table 10- 7 Dimensions and weight
Dimensions W x H x D [mm] 200 x 125 x 118
Weight [g] Approximately 1,150

Table of Contents

Related product manuals