Technical data
10.1 Technical data
SIMOTION C
Operating Instructions, 02/2012
173
Onboard drive interface (C230-2, C240)
Analog
Table 10- 8 Onboard drive interface
Setpoint signal (analog output)
Number 4
Rated voltage range -10.5 to 10.5 V
Output current -3 to 3 mA
Electrically isolated No
Load impedance ≥ 3 kOhm
Resolution
16-bit, including sign (with filter)
12-bit, including sign (without filter)
Filter time
C230-2
C240
With filter (C230-2-compatible)
With filter (C230-2 compatible) or without filter (can
be switched in HW Config)
Basic error limit (at 25° C)
0 V to 10 V
-10 V to 0 V
-2 to +6 % (typically +3 %)
-6 to +2 % (typically -3 %)
Relay contact controller enable
Number 4
Switching voltage max. 50 V
Switching current Max. 1 A
Switching capacity Max. 30 VA
Mechanical service life
Electrical service life
Usually 10
9
switching cycles
Typically 3 · 10
6
switching cycles at 24 V / 1 A
Cable length: Max. 35 m