Interfaces
3.9 Power Module Interface
SIMOTION D410-2
58 Manual, 02/2012
Note
The test sockets are provided as a support to commissioning and diagnostics; they must not
be connected for normal operation.
3.9 Power Module Interface
SIMOTION D410-2 can be connected to a SINAMICS S120 PM340 blocksize power module
via the power module interface.
Figure 3-6 SIMOTION D410-2 interface to the power module interface (PM-IF)
Note
SIMOTION D410-2 can only be connected to a SINAMICS S120 PM340 blocksize power
module via the power module interface. A power module in chassis format must be
connected via the DRIVE-CLiQ interface (see
SIMOTION D410-2
Commissioning and
Hardware Installation Manual).
A SIMOTION D410-2 cannot be operated with SINAMICS G120 (PM2x0) power modules.
Booksize Motor Modules can likewise not be connected.