Technical data
4.2 Mechanical and climatic ambient conditions
SIMOTION D410-2
Manual, 02/2012
61
Ambient conditions Application range Remarks
Mechanical ambient conditions
Pollution degree 2 acc. to EN 60664-1
Biological environmental conditions Class 3B1 according to EN 60 721-
3-3;
mold, mold growth, slime, rodents, termite and
other animal vermin are not permissible.
Chemically active environmental
conditions
Class 3C1 according to EN 60721-
3-3
Mechanically active environmental
conditions
Class 3S1 according to EN 60721-
3-3,
Conductive dusts are not permitted
Note
Observe the application ranges of the PM340 power modules along with their derating. Refer
to
SINAMICS S120 for AC Drives
Manual.
Vibration reduction
If SIMOTION D410-2 is subjected to larger shocks or vibrations, you must use suitable
measures to reduce the acceleration or the amplitude.
We recommend installation on shock-absorbing material (e.g. rubber-metal vibration
dampers).
Other data
Condition Application range
Protection against the ingress of
foreign matter and water
IP20 degree of protection according to EN 60529
Protection class Class 1 (with protective conductor system) and class 3 (PELV)
according to EN 61800-5-1