If no auxiliary contacts are available, overvoltage protection must be used. Protective circuits
with a freewheeling diode or a diode combination with a Z-diode are possible. RC elements and
varistors are not suitable due to the remaining residual voltages.
Additional references
For information on con󹪝guring the digital I/Os as freely addressable I/Os, inputs of measuring
inputs or outputs of output cams, see the SIMOTION D410-2 Commissioning and Hardware
Installation Manual.
For information on the con󹪝guration and function of the measuring input and output cam
technology objects, refer to the SIMOTION Output Cams and Measuring Inputs Function Manual.
Interfaces
4.6 Digital I/Os / temperature sensor / analog input
SIMOTION D410-2
Equipment Manual, 07/2021, A5E33446720B 67