Commissioning
4.8 Using the AS-i Programmer
Distributed converter for SIMOGEAR geared motors
Getting Started, 04/2018, FW V4.7 SP10, A5E36100338B AG
93
Setting the AS-i address of slave 2
1.
Press the
button; the display shows the text
SEArcH
followed
by uSE 0
.
A small 0 is displayed to the left of the display and the number of
the first slave that has already been allocated to slave 1 is shown at
the bottom of the display.
2.
Press the
button to select this number.
SEt 0
appears and the small
0
in the left of the display starts flash-
ing.
3.
Press the
button until you reach the required number.
By pressing both the
and simultaneously, you can toggle between A and B
identifiers of the address.
4.
Press the
button to accept this number.
ProG
is displayed briefly.
Both of the numbers allocated to the slaves are now displayed in
the lower part of the screen.
Changing existing addresses of the AS-i slaves
If the allocated addresses used two different numbers, for example, 10A and 11A, then if one
of the slave addresses is reset to 0 the other slave is not affected.
If the allocated addresses use the same number, for example, 20A and 20B, then if one
slave addresses is reset to 0, then both slaves numbers will be reset to 0.
Modifying an existing address of a single slave within the Inverter will not affect the address
of the other slave.