Commissioning
4.8 Using the AS-i Programmer
Distributed converter for SIMOGEAR geared motors
94 Getting Started, 04/2018, FW V4.7 SP10, A5E36100338B AG
To change an existing address of a slave, the following procedure should be performed:
1.
Plug the AS-i Programmer into the addressing socket of the Inverter
2.
Turn the dial on the Programmer to the ADDR
position. The display
will indicate that this mode has been selected.
3.
Press the
button; the screen will display
uSE
and the number
of the lower addressed slave.
T
he existing slave addresses are shown at the bottom of the dis-
play.
4.
Press the and buttons to select the slave address number to be changed.
5.
Press the
button; the display now shows
SEt
.
The selected number will begin to flash.
6.
Press the
and buttons to select the new slave address
number.
7.
Press the
button to confirm the new address.
ProG
is displayed briefly followed by confirmation of the address
change.