5.5.5 Commissioning wizard
Select the application class
Procedure
When selecting an application class, the converter assigns the motor control with the
appropriate default settings:
[1]
Standard Drive Control (Page144)
[2] Dynamic Drive Control (Page146)
[0] Expert - or if no application class is listed:
Expert (Page148)
Application class Standard Drive Control Dynamic Drive Control
Motors that can
be operated
Induction motors Induction and synchronous motors
Application exam‐
ples
Pumps, fans, and compressors with 󹪞ow char‐
acteristic
Wet or dry blasting technology
Mills, mixers, kneaders, crushers, agitators
Horizontal conveyor technology (conveyor
belts, roller conveyors, chain conveyors)
Basic spindles
Pumps and compressors with displacement ma‐
chines
Rotary furnaces
Extruder
Centrifuges
Commissioning
5.5Quick commissioning with a PC.
SINAMICS G120C Converters
142 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C PN and is the answer not in the manual?

Siemens SINAMICS G120C PN Specifications

General IconGeneral
Power range0.55 kW to 132 kW
Control typeVector control, V/f control
Protection classIP20
Ambient temperature range-10 °C to +50 °C
Product type designationSINAMICS G120C
Integrated SafetySTO (Safe Torque Off)
Operating Temperature-10 °C to +50 °C
Storage temperature range-40 °C to +70 °C
Communication interfacesPROFINET
Output voltage range0 V to input voltage
Overload Capacity150% for 60 s
Relative humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating