→ If you use the internal 10 V power supply, you must connect AI0- or AI1- to GND.
Further wiring options of digital inputs for FSD…FSF
*1'
H[W
9
H[W
'2326

'21(*
',&20




9RXW

*1'

',&20
',
',
',
',
',
',
'212

'2&20
'21&
;
;
;
;
Connection of contacts switching to P potential with an
external power source
If you wish to connect the external
and the internal converter power sup‐
ply voltages with one another, then
you must connect "GND" with termi‐
nals 34 and 69 at the terminals.
*1'
H[W
9
H[W
'2326

'21(*
9RXW

*1'

',&20
',
',
',
',
',
',
'212

'2&20
'21&
;
;
',&20



;

;
Connection of contacts switching to N potential with an
external power source
Connect terminals 69 and 34 at the
terminals.
Installing
4.10Connecting the interfaces for the converter control
SINAMICS G120C Converters
88 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C PN and is the answer not in the manual?

Siemens SINAMICS G120C PN Specifications

General IconGeneral
Power range0.55 kW to 132 kW
Control typeVector control, V/f control
Protection classIP20
Ambient temperature range-10 °C to +50 °C
Product type designationSINAMICS G120C
Integrated SafetySTO (Safe Torque Off)
Operating Temperature-10 °C to +50 °C
Storage temperature range-40 °C to +70 °C
Communication interfacesPROFINET
Output voltage range0 V to input voltage
Overload Capacity150% for 60 s
Relative humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating