General information about SINAMICS Safety Integrated 
  3.1 Supported functions 
Safety Integrated 
Function Manual, 08/2023, A5E03264275A 
15 
•  Safety Integrated Advanced Functions 
These functions require an additional safety license. Advanced Functions with encoder 
require an encoder with safety capability (safety relevant). 
–  Safely-Limited Position (SLP) 
Safely-Limited Position ensures that a freely definable traversing range is not left. 
–  Transferring safe position values (SP) 
The "Transfer safe position values (SP)" function enables you to transfer a safe position 
to a higher-level controller via PROFIsafe. 
–  Safe Cam (SCA) 
The "Safe Cam" function outputs a safe signal if the drive is within a specified position 
range. Safe axis-specific range detection can be implemented using this function. 
1)
 Note on Power/Motor Modules in the chassis format: 
For the chassis format, SBC is only supported by Power/Motor Modules with article number 
...3 or higher. In addition, for this format a Safe Brake Adapter is required. 
For the Chassis-2 format, a Safe Brake Adapter is also required. 
Note 
Parallel use of Safety Integrated Functions
 
All Safety Integrated Functions can be used simultaneously.
 
 
If SOS and SLS are activated simultaneously, SOS has higher priority and overrides the SLS 
reaction.