General information about SINAMICS Safety Integrated
3.1 Supported functions
Safety Integrated
16 Function Manual, 08/2023, A5E03264275A
Invalid operating modes for Safety Integrated Extended Functions "without encoder"
For the independent setting of current controller clock cycle and pulse frequency in
conjunction with Safety Integrated "without encoder", the following system clock cycles
are not permissible:
Power Modules / Motor Modules: <62.5 μs
p9589 = 3300 must be set to allow the current controller clock cycle and pulse
frequency to be independently set.
For Chassis and Chassis-2 format devices, the following also applies:
For Chassis and Chassis-2 format devices, operation without encoder is only
permissible for induction motors, however not for synchronous motors.
No operation involving parallel connections
Optimized pulse patterns cannot be selected
Only using parameter p1810 = factory setting, this includes:
- No wobbling
- No fine setting of the pulse frequency
Induction motors up to a maximum of 1000 kW; for extremely large machines, it is
necessary to adapt parameter p9585