SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
8 A5E52388930A AA, 07/2023
3.2 Mounting the motor
3.2.1 Mounting instructions for the motor
Damage to the absolute encoder due to the magnetic interference from the magnetic field
The magnetic interference from the magnetic field can cause a damage to the absolute encoder.
• To avoid magnetic interference to the absolute encoder, keep the motor at least 15 mm away from devices that produce
a magnetic field stronger than 10 mT.
Permissible conditions for motor operation
Adhere to the specifications on the rating plate.
Observe the safety labels on the motor.
Check the installation site and permissible environmental conditions such as
temperature and installation altitude. For details, see Section "Technical data
of the 1FL2 motor (Page 5)".
Thoroughly remove any anti-corrosion agents from the shaft extension with
commercially available solvents.
Ensure that the flange is in even contact with the mounting surface.
Use hexagon socket head cap screws with a property class of at least 8.8.
Avoid any uneven stressing when tightening the fastening screws.
Table 3-1 Safety labels on the motor
"Hot surface" warning label
"No shocks at the shaft extension" warning label