SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
6 A5E52388930A AA, 07/2023
3 Mounting
3.1 Mounting the converter
3.1.1 Mounting conditions
To ensure a reliable, continuous, and trouble-free converter operation, observe the following mounting conditions:
• The converter is designed for installation in a control cabinet.
• The converter is certified for use in environments with degree of pollution 2 without condensation, that is, in
environments where no conductive pollution/dirt occurs. Condensation is not permissible.
• The converter fulfills degree of protection IP20 according to IEC 60529.
• The converter supports vertical mounting only. Mount the converter vertically with the operator panel facing upwards.
• Use a conductive steel sheet no thinner than 2 mm as the mounting plate.
3.1.2 Dimension drawings and drill dimensions
All dimensions are specified in millimeters.
1 AC/3 AC 200 V
2 x M4 / 2.5 Nm
3 AC 400 V
2 x M4 / 2.5 Nm