4 Configuration and Project Engineering 
4.2 Configuring the SIMATIC controller 
 
SINAMICS V20 at S7-1200/1500 via USS 
Entry ID: 109480894,    V1.0,    09/2018 
 
 Siemens AG 2018 All rights reserved 
4.2  Configuring the SIMATIC controller 
The screenshots in the following table are from the V20USSatS7-1200 STEP 7 
project. Deviations due to the use of the V20USSatS7-1500 project are indicated in 
the text.  
Table 4-2: Table for configuring the SIMATIC S7-1200 controller 
In the project tree, go to Devices & networks and select the Network view. In the Hardware catalog 
task card, locate the SIMATIC S7-1200 CPU 1215C DC/DC/DC or SIMATIC S7-1500 CPU 1511-1 
PN and use drag and drop to move it to the graphic area of the Network view. In this area and in 
the project tree, it will be created as PLC_1
6
. Select the CPU with a version ≥V4.1 (S7-1200) or 
≥V1.7 (S7-1500).  
 
 
 Name can be changed.